- General Information
- Manufacturer
- Schneider Electric SA
- Manufacturer Website Address
- http://www.schneider-electric.com.au
- Brand Name
- APC by Schneider Electric
- Product Line
- Symmetra
- Product Series
- LX
- Product Type
- Double Conversion Online UPS
Symmetra LX 8kVA Scalable to 16kVA Rack-mountable/Tower UPS is high performance, redundant power protection with scalable power and runtime for space-constrained computer rooms and voice and data networks. Engineered to deliver the highest level of business continuity possible, the Symmetra LX uses a modular, redundant architecture that can scale power and run-time as demand increases or when higher levels of availability are required. Advancements in this next generation design greatly decrease foot print or U-space needed in an equipment rack, increase speed and ease of deployment and reduce repair time. With built-in network manageability and a comprehensive portfolio available from 4-16 kVA N+1, the on-line Symmetra LX is the choice to protect high-performance IT and telecom equipment in computer rooms and small data centers.
- Warranty
- Limited Warranty
- 2 Year
- Technical Information
- Overload Protection
- Yes
- Power Description
- Load Capacity (VA)
- 16 kVA
- Input Voltage
- 220 V AC
- Waveform Type
- Sine Wave
- Management
- Network Management
- SNMP Manageable
- Alarm
- Self-test Operation
- Emergency Power OFF
- Yes
- Interfaces/Ports
- Modular Slots
- 1 x SmartSlot
- Battery Information
- Battery Characteristics
- Spill-proof/Maintenance-free
- Battery Chemistry
- Lead Acid
- Environmental Conditions
- Thermal Dissipation
- 3707 BTU/h
- Physical Characteristics
- Color Family
- Dual Colour
- Form Factor
- Rack/Tower
- Rack Height
- 19U
- Height
- 838.2 mm
- Width
- 472.4 mm
- Depth
- 690 mm
- Weight (Approximate)
- 198.64 kg
- Miscellaneous
- Package Contents
- Symmetra LX 8kVA Scalable to 16kVA Rack-mountable/Tower UPS
- CD with software
- Documentation CD
- Installation Guide
- User Manual
- Web/SNMP Management Card
- Additional Information
- Output Voltage Distortion: Less than 5% at full load
- Crest Factor: Up to 5 : 1
- Efficiency at full load: 90 %
- Replacement battery cartridge quantity: 2
- Units per Pallet: 1
- Automatic restart of loads after UPS shutdown
- Generator compatible
- InfraStruXure Manager Compatible
- Input power factor correction
- Certifications & Standards
- C-tick
- CE
- EN 50091-1
- EN 50091-2
- EN 55022 Class A
- EN 55024
- EN 60950
- GOST
- IEC 60950
- VDE